1 Ivybrook Blvd. Suite 130 Ivyland, PA 18974
215-675-8670








Instrumentation
UE Systems
Leak Detection Equipment
Fox
Fox Thermal Flow Meters for Compressed Air and Other Gases
Nyad
Moisture Analyzers
Oxygen Analyzers
Carbon Monoxide Analyzers
Combination Analyzers

UE Systems Leak Detection Equipment
Leak Detection Applications
Pressure and vacuum leak detection
Hydraulic valve bypass
Exhaust system leaks
Heat exchangers, boilers, condensers
Valve and steam trap inspection
Bearing testing
Gear / gear box inspection
Cockpit window leaks
General mechanical inspection
Tanks, pipes, leak testing, etc
Electrical inspection
UE Systems ultrasonic instruments for leak detection are used in energy conservation, predictive maintenance, and safety and quality assurance programs. The Ultraprobe Series is recognized as the standard in portable airborne ultrasound instrumentation. Supported by an array of specialized accessories and software, UE Systems also provides continuous online monitors for quality control and advanced warning of leaks.

Ultraprobe 2000
UE Systems Ultraprobe 2000UE Systems’ Ultraprobe 2000 is an ultrasonic inspection instrument. The Ultraprobe 2000 works in simple and sophisticated leak detection applications. UE Systems designed user-friendly features into the Ultraprobe 2000 to make it easy-to-use and functional in the field. Features include:
  • Frequency tuning – allows the operator to select the specific frequency of a problem sound. Selecting a specific frequency has the added benefit of reducing interference from ultrasonic signals generated by nearby equipment.
  • Bi-modal meter switch – Logarithmic metering for instant leak detection and fault detection response and Linear mode for bearing and mechanical monitoring, which accepts a wide range of sounds that is averaged for stabilized readings
  • Ten turn sensitivity adjust dial – helps operators detect subtle mechanical and leak problems as well as focus in on gross signals
  • Trisonic scanning module – patented transducer has a phased array of three transducers delivering sensitivity previously not attainable
    Specifications
    Construction Metered pistol anodized aluminum and ABS plastic
    Circuitry Solid-state heterodyne receiver with temperature compensation
    Frequency Detects ultrasonic frequencies between 20 kHz and 100 kHz
    Response Continuously variable. Frequencies are converted to 50 Hz to 3 kHz audio

    UE Systems Ultraprobe 2000 Kit
    Ultraprobe 2000 Kit Complete
  • Trisonic Scanning Module
  • Rubber Focusing Probe
  • Stethoscope Probe
  • Deluxe Industrial Noise Reducing Headset
  • Video Training Tape Program
  • Extension Probe Kit
  • Warble Tone Generator
  • Battery Recharge Kit
  • Zero Halliburton Aluminum Carrying Case
    Ultraprobe 9000
  • Open platform software
  • Interchangeable modules
  • Frequency tuning
  • Spin and Click technologyUE Systems Utraprobe 9000
  • 120 dB Dynamic range
  • 400 Memory locations record: dB, time, frequency, date, text, operation mode, and more
  • Acoustic isolating headphones
  • Environmentally friendly rechargeable batteries
  • Superior application support
  • Easy interface for most vibration analyzers including: SKF, ENTEK, DLI, CSI, DI
  • Developed by the industry leader in airborne ultrasound
    Ultraprobe 9000 Kit Complete
  • DHC-2 Deluxe Noise Isolating HeadsetUE Systems Utraprobe 9000 Kit
  • WTG-1 Warble Tone Generator
  • RFE-9 Rubber Focusing Probe
  • 5PC-C9 I/O Cable
  • BCH-9 Battery Charger
  • BCH-WTG Battery Charger
  • SCM-9 Trisonic Scanning Module
  • STM-9 Stethoscope (Contact) Module
  • SLP-EXT Stethoscope Extension Kit
  • Pistol-Grip Housing
    Ultraprobe 550
    UE Systems Ultraprobe 550 Kit
  • Auditory channels (via an acoustically isolating headset)UE Systems Ultraprobe 100
  • Analog meter
  • Demodulated signal for vibration data collectors and FFT’s
  • Kits also available
    Ultraprobe 100
  • Heterodynes signals into audible range
  • Sounds come through headset and also display as intensity increments on the meter
  • Kits also available
    UCA 586
    Typical applications:UE Systems UCA 586
  • Bearing monitoring
  • Valve leak monitoring
  • Flow/No Flow
  • Solid Flow Detection
  • Electrical
  • Cavitation Monitor
  • Coal Fineness Monitor
  • Bearing lubrication failure
  • Gearbox monitor
    DS 386
    UE Systems DS 386
  • Fast response
  • Real-time testing
  • High Volume Testing
  • Choice of test modes: gross or fine
  • Unique modular sensitivity validation
  • Modular “plug and play circuitry”
  • Low maintenance
  • Ease of installation
  • Choice of sensor arrays
    Accessories
  • Long Range Module – advanced technology from UE Systems and National Aeronautics and Space Administration
  • Close Focus Module – a specialized module to help locate low level leaks
  • Ultrasonic Wave Form Concentrator – doubles the detection range and pinpoints ultrasonic emissions at great distances
  • Liquid Leak Amplifier – for low level leaks down to 1 x 10-6 std. Ml/sec.
  • Warble Tone Generators – for leak detection without pressure or vacuum
  • Magnetic Mount Probes – transducers and male connecting pins for attachment to the STM-2, STM-9, or STM-1 stethoscope modules
    Specification Sheets (pdf format)

    Fox Thermal Flow Meters for Compressed Air and Other Gases
     

    Thermal Insertion and Inline Flow Meters Offer Precision Air and Fuel Flow Measurement

    Every mass flow meter sold by Fox Thermal Instruments is based on the thermal sensing principle. This proven flow technology helps plant managers improve productivity and reduce costs. Our advanced digital flow meters feature rugged industrial packaging and are available in a variety of insertion and inline configurations, making them the ideal instrument for a wide range of precision industrial and commercial air and gas flow applications.

    Leading edge designs by Fox Thermal Instruments include:


    Model FT2 Thermal Gas Flow Meter and Temperature Transmitters
     

    Model FT2 Thermal Gas Flow Meter & Temperature Transmitters - FM & FMc approved!

    Inline and insertion flow meters with smart digital electronics and NEMA 4X enclosures accommodate a wide range of gas, fuel and oxygen flow rates. The Fox Power Pro sensor operates at a higher power level than competitive models, resulting in the fastest response time and widest turndown of any thermal flow meter.

    More on FT2 Thermal Gas Flowmeter & Temperature Transmitters
     

    Model 10A Thermal Gas and Fuel Flow Meters
     

    Model 10A Thermal Gas & Fuel Flow Meters

    Providing a direct reading of air or gas mass flow rate, these rugged flow meters feature explosion-proof enclosures and are FM and CSA approved for Class I, Division 1, Groups B, C and D hazardous areas. Common applications include compressed air and natural gas measurement.

    More on Model 10A Thermal Gas Flowmeters
     

    Model SW100 Flow and Level Switch for liquids and gases
     

    Model SW100 Flow & Level Switch for Liquids and Gases

    These versatile flow and level switches are designed for gas, liquid and slurry applications, and are approved for Class I, Division 1, Groups B, C, and D hazardous areas.

    More on Model SW100 Flow & Level Switch for Liquids and Gases

    Gas Flow Meter and Air Flow Meter Applications

    Our air and gas flow meters are designed for use in a wide variety of applications, including inert and explosive gases as well as mixed and corrosive gases. By utilizing rugged stainless steel or Hastelloy wetted materials, Fox Thermal Instruments' devices provide precision performance and outstanding durability. Inline and insertion flow meters have demonstrated their accuracy, reliability and low cost-of-ownership in these and many other applications:

    • compressed air monitoring
    • oxygen flow monitoring
    • natural gas to boilers, burners and other combustion processes
    • wastewater aeration
    • hydrogen metering
    • land fill gas measurement
    • purge monitoring
    • flare gas monitoring
    • exhaust gas measurement
    • chlorine metering

    Nyad Moisture Analyzers
    The A.C.T. (Advanced Capacitive Transducer) moisture sensor uses state-of-the-art technology to produce a fast-responding, rugged, trace moisture sensor that is also designed to lower your costs by permitting sensor replacement without having to discard old probe bodies. The A.C.T. technology has dramatic improvements in its performance as well as a high specificity to moisture compared to older, competitive versions.
  • Wide dynamic range: -130°C to +20°C Dew/FrostpointNYAD Moisture Analyzer
  • Selectable units: °C, °F, or ppm
  • High pressure (7000 psig)
  • Active pressure correction
  • Remote sensor (to 1000 ft.)
  • Adjustable alarm contacts
  • Large 4 digit LCD
  • Non-volatile data memory
  • O.E.M. packaging
  • Gas or liquid samples
  • Analog output (voltage or current)

    Nyad Oxygen Analyzers
    These analyzers use a replaceable electrochemical cell, and among its advanced features are its lower temperature coefficient due to diffusion barrier design, immunity to CO2, and its wide range. It provides more than a year’s life in normal applications, and it is suitable for multi-background gas samples.
  • Microprocessor based electronicsNYAD Oxygen Analyzer
  • Large 4 digit display
  • Direct reading oxygen concentration
  • Auto ranging (0-100 ppm, 0-10,000ppm, 0-100%)
  • Auto calibration with air or span gases
  • Remote sensor module (to 1000 ft.)
  • Adjustable alarm contacts
  • Analog output (Voltage or Current)
  • Low temperature coefficient
  • O.E.M. packaging

    Carbon Monoxide Analyzers
    These monitors were designed to accurately and reliably monitor the Carbon Monoxide content of high pressure breathing air or medical air supplies and provide an alarm when safe levels are exceeded. They feature an advanced electrochemical sensor whose digitized output is sent to a microprocessor-based analyzer that provides a digital display of Carbon Monoxide concentration.
  • Microprocessor based controllerNYAD Carbon Monoxide Analyzer
  • Auto calibration
  • Adjustable alarm contacts
  • Audible alarm
  • Operating range: (0 to 2000 ppm CO)
  • Electrochemical sensor
  • Large 4 digit LCD display
  • Analog output (Voltage or Current)
  • O.E.M. packaging
    Combination Analyzers

    Trace Gas / H2O Analyzers
    These analyzers measure both moisture and Oxygen concentrations in gas samples. In one package you have the convenience of two independent gas analyzers with separate displays, outputs, and alarms.
  • Independent analyzers for each measurement NYAD Trace Gas / H2O Analyzer
  • Interchangeable signal processing electronics
  • Wide dynamic range: -130°C to +20°C Dew/Frostpoint
  • Selectable units (°C, °F or ppm Moisture)
  • Direct Reading PPM (0 to 9999 Oxygen)
  • Auto ranging/Auto calibration using air or span gases (Oxygen)
  • Remote sensors (to 1000 ft.)
  • Adjustable alarm contacts
  • Two large 4 digit LCD displays
  • Non-Volatile data memory
  • O.E.M. packaging
    Moisture / Carbon Monoxide Analyzers
    These analyzers were designed to accurately and reliably measure both moisture and Carbon Monoxide concentrations in breathing air or medical air supplies as well as provide alarms when safe levels are exceeded. In one package, the 600 series offers two independent analyzers with separate displays, outputs and alarms.
  • Independent analyzers for each measurement NYAD Moisture / Carbon Monoxide Analyzer
  • Microprocessor based electronics
  • Wide dynamic range, Moisture: -130°C to +20°C Dew/Frostpoint
  • Selectable units: (°C, °F, or ppm, Moisture)
  • Direct reading Carbon Monoxide concentration: 0-2000 ppm
  • Auto calibration (CO)
  • Adjustable alarm contacts
  • Analog output (Voltage or Current)
  • Two 4 digit LCD displays
  • O.E.M. packaging